The error "Could not run scripting .DLL" displays when you start the administration program. This symptom is only for version 6 and older of MailEnable.
This is resolved by following the instructions below to manually re-register "scrrun.dll" file.
1. Navigate to Start > Run command
2. In the Run command,
type one of these command lines:
For 32bit Windows:
regsvr32.exe C:\windows\system32\scrrun.dll
For 64bit Windows:
regsvr32.exe C:\windows\syswow64\scrrun.dll
If the error stil occurs, make sure UAC is turned off before registering the DLL.